3-11
3
3.5 Initial Setting
After turn on the JUE-87 MES, set the following parameters;
(1) Selecting Preferred Ocean Region
(2) Setting Date & Time
(3) Setting Peripheral Function
3.5.1 Selecting Preferred Ocean Region (Ncs/Les info)
When a particular ocean region is selected, the MES will scan the NCS common channel only in the
ocean region selected.
NOTE
1)The Selecting Preferred Ocean Region command is available, when the first line of the screen is
displayed “Ready”, “Log-out”, or “EGC only”.
2)In case of “All ocean region” setup, if MES does not receive NCS common channel more than
30minutes, MES automatically scans all ocean region and tunes new NCS common channel. However,
MES automatically does not login. Please login manually. (The information is displayed on IME/DTE
screen to user.)
Step
Operation/Response (Example)
Screen (Example) Remarks
1
Move the cursor to
“Ncs/les-info” with
using the arrow keys and
press
Enter key.
The “Ncs/les
information”
window is
displayed.
2
Move the cursor to
“Preferred ocean
region” and press
Enter
key.
The “Preferred
ocean region
window is
displayed.
3
Confirm the cursor is at
“All ocean region” and
press
Enter key.
Status display is
changed from
Ready” to
Scan”.
When you want to change a
parameter, move the cursor to the
item you want and press
Enter
key.
You cannot set up when the status
in the first line on the main menu
is “Tune”.
In this case, change the parameter
during “Log-out” or “EGC only”
displayed in the first line (about 3
seconds), by switching the IME
power source OFF and ON.
4
To return to Main menu
screen, press
Esc key.
Windows are
disappeared.

Table of Contents