3-89
3
3.12.5 Parameter Setting Polling for Scheduled Transmission
Parameters of scheduled transmission are changeable from IME/DTE or the polling from land based
user. Firstly, land based user should read out the parameters with parameter read out command. Land user
will acquire the access code and parameters. The access code is changed by each command of reading out
and is required to change the parameters. Secondly, land user should change the parameters. When the
correct command is included in the receive message, the MES checks the access code then change the
parameters.
Command for parameters read out polling
/SR/XXX:XXX.....XXX/X..X/
Network type [TELEX, PSDN or Vxx (for PSTN)]
Subscribers number (up to 11-digit)
Destination code (3-digit)
Example of parameter read out polling
MES receives the following message:
/SR/072:02822351/TELEX/
MES transmits the following message to the land based user, destination code: 072, subscribers
number: 02822351 via Telex:
MES NUMBER: 412345678
SCHEDULE
1 START 96-10-10 19:00
INTERVAL 12:00
LES 202
DESTINATION 123-123456789
NETWORK TELEX
CHARACTER IA5
DATA DS1 DS2
TRANSMIT ON
DELAY LOGGING OUT 00:00
ACCESS CODE: 123456
96-01-25