3-90 
Command for parameter setting
 
/SP/XXXXXX
/X/XXXXXX/XXXX/XXXX/XXX/X..X/XXX:X...X/X..X/X..X/X.X/ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Example of parameter setting
 
MES receives the following message: 
/SP/123456/1/930515/1200/0600/101/V22B/001:1234567890/DATA/DS1/ON/ 
 
MES changes the parameters as follows: 
1 START         96-05-15  12:00 
  INTERVAL      06:00 
  LES           101 
  DESTINATION   001-1234567890 
  NETWORK       PSTN (V22B) 
  CHARACTER     DATA 
  DATA          DS1 
  TRANSMIT      ON 
Access code 
Schedule number 
Start date [YYMMDD] 
Start time [HHMM] 
Interval [HHMM] 
LES ID 
etwork type [TELEX, PSDN, Vxx (for PSTN)] 
Destination code (3-digit) 
Subscriber’s number 
Destination code [4-digit for PSDN 
3-digit for TELEX and PSTN] 
Presentation [IA5, ITA2 or DATA] 
Data type [DS0, DS1, 
DS2, P or combination] 
Transmission 
[ON or OFF]