3-90
Command for parameter setting
/SP/XXXXXX
/X/XXXXXX/XXXX/XXXX/XXX/X..X/XXX:X...X/X..X/X..X/X.X/
Example of parameter setting
MES receives the following message:
/SP/123456/1/930515/1200/0600/101/V22B/001:1234567890/DATA/DS1/ON/
MES changes the parameters as follows:
1 START 96-05-15 12:00
INTERVAL 06:00
LES 101
DESTINATION 001-1234567890
NETWORK PSTN (V22B)
CHARACTER DATA
DATA DS1
TRANSMIT ON
Access code
Schedule number
Start date [YYMMDD]
Start time [HHMM]
Interval [HHMM]
LES ID
etwork type [TELEX, PSDN, Vxx (for PSTN)]
Destination code (3-digit)
Subscriber’s number
Destination code [4-digit for PSDN
3-digit for TELEX and PSTN]
Presentation [IA5, ITA2 or DATA]
Data type [DS0, DS1,
DS2, P or combination]
Transmission
[ON or OFF]