11
ENGLISH
4. Piping pneumatic components and wiring electric components
Perform piping of the pneumatic components and wiring of the electric components in accordance with the drawing below.
Air pressure required for this sewing machine is 0.5 MPa.
Turn the dial to adjust the pressure to 0.5 MPa after
completion of piping.
Fix the air unit on the table with wood screws.
(For the xing position, refer to the drawing of table for
reference.)
0.5 MPa
40004065
40004041
CN36 CN33CN37CN56
SC-921
Wiring diagram of pneumatic and electric components
22951552 (Earth cord)
Gray
Black
DLN-6390-7 Machine main unit
Take care of color
when connecting
connectors.
40003754 Accessories
Air tube (Yellow)
Air tube (Blue)
Air tube (Green)
Air tube (Red)
Air tube (White)
Air tube (Black)
1.3 M
Optional
40033334 Accessories
40106208 Optional
Air tube (Black)
1.2 M
Air tube (Black)
0.15 M
Optional
Black
White
PC012401000 Optional
PV150103000 Optional