Table 11: PTX10001-36MR AC/HVDC Power Supply Status LED Descripon
(Connued)
LED Color LED State Descripon
Amber On steadily
The power supply module shut down
due to a crical event. Possible
causes: high temperature, high power,
high current, or fan failure.
The AC power cord is unplugged.
Blinking The power supply module is operang but
there are warning events. Possible
condions: high temperature (inlet
temperature is greater than 53° F [11° C]
or a hot spot temperature is greater than
95° F [35° C]), high power, high current,
or slow fan (less than 1200 rpm).
You can get addional informaon about the status of the power supply modules using the show chassis
power command and the show chassis power detail command. Here are some examples of the CLI output:
PTX10001-36MR with Two AC/HVDC Power Supplies
user@device> show chassis power
Chassis Power Voltage(V) Power(W)
Total Input Power 1020
PSM 0
Input 1 230 603
Output 12.02 525.93
PSM 1
Input 1 232 417
Output 11.99 346.21
user@device> show chassis power detail
Chassis Power Voltage(V) Power(W)
Total Input Power 1023
PSM 0
Input 1 229 604
Output 12.02 533.45
29