CAN Triggering and Serial Decode 25
Keysight InfiniiVision 1200 X-Series and EDUX1052A/G Oscilloscopes User's Guide 283
In addition to the standard Time column, the CAN Lister contains these columns:
ID — frame ID.
Type — frame type (RMT remote frame or Data).
DLC — data length code.
•Data data bytes.
CRC — cyclic redundancy check.
Errors — highlighted in red. Errors can be Acknowledge (Ack, A), Form (Fo), or
Frame (Fr). Different kinds of errors can be combined like "Fo,Fr" in the above
example.
Aliased data is highlighted in pink. When this happens, decrease the horizontal
time/div setting and run again.