296 Keysight InfiniiVision 1200 X-Series and EDUX1052A/G Oscilloscopes User's Guide
27 LIN Triggering and Serial Decode
3 Press the Trigger Type softkey; then, turn the Entry knob to select the serial slot
(Serial 1) on which the LIN signal is being decoded.
4 Press the Trigger on: softkey; then, turn the Entry knob to
select the trigger condition:
• Sync (Sync Break) — The oscilloscope triggers on the rising
edge at the Sync Break exit of the LIN single-wire bus
signal that marks the beginning the message frame.
• ID (Frame ID) — The oscilloscope triggers when a frame
with an ID equal to the selected value is detected. Use the
Entry knob to select the value for the Frame ID.
• ID & Data (Frame ID and Data) — The oscilloscope triggers
when a frame with an ID and data equal to the selected
values is detected. When triggering on a frame ID and
data:
• To select the frame ID value, press the Frame ID softkey,
and use the Entry knob.
Note that you can enter a "don't care" value for the
frame ID and trigger on data values only.
• To set up the number of data bytes and enter their values (in hexadecimal
or binary), press the Bits softkey to open the LIN Bits menu.