Maintenance
Description
item No.
2FD/2FF/2FG-3.0
1-4-74
U990 Checking/clearing the time for the exposure lamp to light
Description
Displays, clears or changes the accumulated time for the exposure lamp to light.
Purpose
To check duration of use of the exposure lamp. Also to clear the accumulated time for the lamp after
replacement.
Method
Press the start key. The accumulated time of illumination for the exposure lamp is displayed in minutes.
Clearing
1. Press the reset key.
2. Press the start key. The accumulated time is cleared, and the screen for selecting a maintenance item No.
is displayed.
Setting
1. Enter a six-digit accumulated time using the numeric keys.
2. Press the start key. The time is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the accumulated time, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U991 Checking the scanner count
Description
Displays the scanner operation count.
Purpose
To check the status of use of the scanner.
Method
Press the start key.
Display Description
COPY SCAN COUNT Scanner operation count for copying
FAX SCAN COUNT Scanner operation count for fax
NT SCAN COUNT Network scanner operation count
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.