EasyManua.ls Logo

Kyocera TASKalfa 181

Kyocera TASKalfa 181
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2KJ/2KH
1-4-17
(2) Self diagnostic codes
Code Contents
Remarks
Causes Check procedures/corrective measures
C0030 Fax control PWB system problem
Processing with the fax software was
disabled due to a hardware or software
problem.
Defective fax con-
trol PWB.
Replace the fax control PWB and verify the
operation.
C0070 Abnormal detection of fax control
PWB incompatibility
Fax software is not compatible with main
software
Fax software or
main software is
something of the
other machine.
Check the version of the fax software and
the main software, upgrade the version to
the compatible software.
C0100 Backup memory (EEPROM) device
problem (Main PWB)
Reading from or writing to EEPROM
cannot be performed.
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
C0110 Backup memory data problem (Main
PWB)
Data in the specified area of the backup
memory does not match the specified
values.
Data damage of
EEPROM.
Contact the Service Administrative Division.
C0130 Backup memory device problem
(Main EEPROM)
Reading from or writing to EEPROM
cannot be performed.
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
Device damage of
EEPROM.
Contact the Service Administrative Division.
C0140 Backup memory data problem
(Main EEPROM)
Reading data from EEPROM is abnor-
mal.
Data damage of
EEPROM.
Contact the Service Administrative Division.
C0150 Backup memory device problem
(Engine EEPROM)
Reading from or writing to EEPROM
cannot be performed.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
Device damage of
EEPROM.
Contact the Service Administrative Division.
C0160 Backup memory data problem
(Engine EEPROM)
Reading data from EEPROM is abnor-
mal.
Data damage of
EEPROM.
Contact the Service Administrative Division.
C0170 Copy counts problem
When the power is turned on, the total
count and the scan count are abnormal
both on the main PWB and the engine
PWB.
Data damage of
EEPROM.
Contact the Service Administrative Division.
Defective PWB. Replace the main PWB or engine PWB and
check for correct operation.
C0180 Machine number mismatch
Machine number of main PWB and
engine PWB does not match.
Data damage of
EEPROM.
Contact the Service Administrative Division.