2KJ/2KH
1-5-3
1-5-2 Paper feed section
(1) Detaching and refitting the separation pulley
Follow the procedure below to replace the separation pulley.
Procedure
1. Open the front cover and left cover.
2. Pull out the cassette.
Figure 1-5-3
3. Remove the screw and remove the front left
lower cover.
Figure 1-5-4
Cassette
Screw
Front left
lower cover