2KJ/2KH
1-3-38
U157
Checking/clearing the developing drive time
Description
Displays the developing drive time for checking, or clearing a figure, which is used as a reference when cor-
recting the toner control.
Purpose
To check the developing drive time after replacing the developing unit.
Method
1. Press the start key. The developing drive time is displayed in minutes.
Setting
1. Select [TIME(M)] using the cursor up/down keys.
2. Enter a drive time (in minutes) using the numeric key.
3. Press the start key. The time is set.
Clearing
1. Select [CLEAR] using the cursor up/down keys.
2. Press the start key. The time is cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U158
Checking the developing count
Description
Displays the developing count for checking.
Purpose
To check the developing count after replacing the developing unit.
Method
1. Press the start key. The developing counter count is displayed.
Setting
1. Select [COUNT] using the cursor up/down keys.
2. Change the count using the numeric key.
3. Press the start key. The count is set.
Clearing
1. Select [CLEAR] using the cursor up/down keys.
2. Press the start key. The count is cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
3. Change the setting using the cursor left/right keys.
4. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display Description Setting range Initial setting
1ST TEMP
Primary stabilization fixing temperature
120 to 185 145
2ND TEMP
Secondary stabilization fixing temperature
120 to 185 165
COPY TEMP1
Copying operation temperature 1
160 to 220 175
COPY TEMP2
Copying operation temperature 2
160 to 220 185
UP TEMP Step-up operation temperature 1 to 99 1
DOWN TEMP Step-down operation temperature 1 to 99 2