2KJ/2KH
1-4-28
(6) A black line appears longitudinally.
(7) A black line appears laterally.
(8) One side of the copy image is darker than the other.
(9) Black dots appear on the image.
Copy example Causes Check procedures/corrective measures
Dirty contact glass. Clean the contact glass.
Dirty or flawed drum. Clean the drum or, if it is flawed, replace the drum unit (see
page 1-5-41).
Dirty scanner mirror. Clean the scanner mirror.
Dirty main charger wire. Clean the wire or, if it is extremely dirty, replace the main
charger unit (see page 1-5-43).
Copy example Causes Check procedures/corrective measures
Dirty contact glass. Clean the contact glass.
Dirty or flawed drum. Clean the drum or, if it is flawed, replace the drum unit (see
page 1-5-41).
Dirty developing section. Clean any part contaminated with toner in the developing
section.
Leaking main charger housing. Clean the main charger wire and grid.
Leaking separation electrode. Clean the separation electrode.
Copy example Causes Check procedures/corrective measures
Dirty main charger wire. Clean the wire or, if it is extremely dirty, replace the main
charger unit (see page 1-5-43).
Defective exposure lamp. Check if the exposure lamp light is distributed evenly. If not,
replace the exposure lamp (see page 1-5-24).
Copy example Causes Check procedures/corrective measures
Dirty contact glass. Clean the contact glass.
Dirty or flawed drum. Clean the drum or, if it is flawed, replace the drum unit (see
page 1-5-41).
Deformed or worn cleaning blade. Replace the drum unit (see page 1-5-41).
Dirty drum separation claws. Clean the drum separation claws.
Dirty the heat roller separation claws. Clean the heat roller separation claws.