2KJ/2KH-1
1-5-20
9. Remove the stop ring, MP paper guide,
spring pin and the MP paper feed pulley.
Figure 1-5-31
10. Push the inserted parts of the MP separation
pad and remove the pad from the machine.
11. Replace the MP paper feed pulley and MP
separation pad and refit all the removed
parts.
Cautions
Confirm that the MP paper guide does not
rotate (locked) after refit the MP paper feed
pulley unit.
Figure 1-5-32
MP paper guide
Stop ring
MP paper feed pulley
Spring pin
MP paper feed pulley shaft
MP separation pad
MP separation pad