EasyManua.ls Logo

Lenovo ThinkSystem SR655 V3 - Page 61

Lenovo ThinkSystem SR655 V3
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
CAUTION:
Hazardous moving fan blades nearby. Keep fingers and other body parts away.
Attention:
Read
“Installation Guidelines” on page 35 and “Safety inspection checklist” on page 36 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 42.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BashWCNZQEDP7o3EohXPEV
.
Procedure
Note: The illustrated air baffle is the standard air baffle. The removal procedure is the same for the GPU air
baffle.
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 43.
b. Remove the top cover. See
“Remove the top cover” on page 148.
c. If there is a RAID flash power module installed on the air baffle, disconnect the cable of the
RAID flash power module.
Step 2. Grasp the air baffle and carefully lift it out of the chassis.
Attention: For proper cooling and airflow, reinstall the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Chapter 5. Hardware replacement procedures 51

Table of Contents

Related product manuals