Function library
Function blocks
9.2.24 Control of the drive controller (DCTRL)
9-93
L
EDSVS9332S-D11 EN 3.0
Signal Source Note
Name Type DIS DIS format CFG List Lenze
DCTRL-CINH1 d C0878/1 bin C0870/1 2 1000 HIGH = inhibit controller
DCTRL-CINH2 d C0878/2 bin C0870/2 2 1000 HIGH = inhibit controller
DCTRL-TRIP-SET d C0878/3 bin C0871 2 54 HIGH = fault indication EEr
DCTRL-TRIP-RESET d C0878/4 bin C0876 2 55 LOW-HIGH signal = Trip reset
DCTRL-PAR*1 d C0884/1 bin C0880/1 2 1000 Selecting a parameter set
DCTRL-PAR*2 d C0884/2 bin C0880/2 2 1000 Selecting a parameter set
DCTRL-PAR-LOAD d C0884/3 bin C0881 2 1000 LOW-HIGH edge = Loading a parameter set
DCTRL-QSP d - - - - - HIGH = drive performs quick stop
DCTRL-RDY d - - - - - HIGH = Ready for operation
DCTRL-CINH d - - - - - HIGH = Controller reset
DCTRL-IMP d - - - - - HIGH = High-resistance power output
stages
DCTRL-TRIP d - - - - - HIGH = Active fault
DCTRL-WARN d - - - - - HIGH = Active warning
DCTRL-MESS d - - - - - HIGH = Active message
DCTRL-FAIL d - - - - - -
DCTRL-CW/CCW d - - - - - LOW = CW rotation, HIGH = CCW rotation
DCTRL-NACT=0 d - - - - - HIGH = Motor speed < C0019
DCTRL-STAT*1 d - - - - - general status (binary coded)
DCTRL-STAT*2 d - - - - - general status (binary coded)
DCTRL-STAT*4 d - - - - - general status (binary coded)
DCTRL-STAT*8 d - - - - - general status (binary coded)
DCTRL-INIT d - - - - - -
DCTRL-PARBUSY d - - - - HIGH = parameter set changeover is active
DCTRL-PAR*1-O d - - - - - Parameter set X is active (binary coded)
DCTRL-PAR*2-0 d - - - - - Parameter set X is active (binary coded)
Function
z Quick stop (QSP)
z Operation inhibited (DISABLE)
z Controller inhibit (CINH)
z TRIP-set
z TRIP-RESET
z Change of parameter set (PAR)
z Controller state
9.2.24.1 Quick stop (QSP)
The drive is braked to standstill via the deceleration ramp C105 and generates a holding torque.
z The function can be controlled by three inputs
Control word CAN-CTRL bit 3 of CAN-IN1
Control word AIF-CTRL bit 3 of AIF-IN
Control word C0135 bit 3
z All inputs are linked by an OR-operation.
z C0136/1 displays the control word C0135