Function library
Function blocks
9.2.24 Control of the drive controller (DCTRL)
9-94
L
EDSVS9332S-D11 EN 3.0
9.2.24.2 Operation inhibit (DISABLE)
Inthis stateit is not possibleto start thedriveby thecommand ”Controller enable”.Thepoweroutput
stages will be inhibited. All controllers will be reset.
z The function can be controlled by three inputs
– Control word CAN-CTRL bit 8 of CAN-IN1
– Control word AIF-CTRL bit 8 of AIF-IN
– Control word C0135 bit 8
z All inputs are linked by an OR-operation.
z C0136/1 displays the control word C0135
9.2.24.3 Controller inhibit (CINH)
The power output stages will be inhibited. All controllers will be reset.
z The function can be controlled by six inputs
– Terminal X5/28 (LOW = controller inhibit)
– Control word CAN-CTRL bit 9 of CAN-IN1
– Control word AIF-CTRL bit 9 of AIF-IN
– Control word C0135 bit 9
– Free inputs DCTRL-CINH1 and DCTRL-CINH2
z All inputs are linked by an OR-operation.
z C0136/1 displays the control word C0135
9.2.24.4 TRIP-SET
The drive is controlled into the state under code C0581 and indicates EEr (external monitoring).
z The function can be controlled by four inputs
– Control word CAN-CTRL bit 10 of CAN-IN1
–ControlwordAIF-CTRLbit10ofAIF-IN
– Control word C0135 bit 10
– Free input DCTRL-TRIP-SET
z All inputs are linked by an OR-operation.
z C0136/1 displays the control word C0135