Function library
Function blocks
9.2.24 Control of the drive controller (DCTRL)
9-95
L
EDSVS9332S-D11 EN 3.0
9.2.24.5 TRIP-RESET
Resets a pending trip if the fault has been remedied. If the cause of malfunction is still active, no
reaction takes place.
z The function can be controlled by four inputs
Control word CAN-CTRL bit 11 of CAN-IN1
–ControlwordAIF-CTRLbit11ofAIF-IN
Control word C0135 bit 11
Free input DCTRL-TRIP-RESET
z All inputs are linked by an OR-operation.
z The function can only be performed by a LOW-HIGH edge of the signal resulting from the OR
operation.
z C0136/1 displays the control word C0135
Tip!
If one of the inputs is set to HIGH, no LOW-HIGH edge can occur at the resulting signal.