Function library
Function blocks
9.2.54 Phase integrator (PHINT)
9-187
L
EDSVS9332S-D11 EN 3.0
9.2.54.3 Input value with sign reversal (PHINT3)
C1150 = 2
The input PHINT3-LOAD is state-controlled (HIGH level).
z PHINT3-LOAD = HIGH
The integrator is loaded with the input value at PHINT3-SET.
Sets the output PHINT3-STATUS = LOW.
P H I N T 3 - O U T
P H I N T 3 - S T A T U S
C 1 1 5 1
- C 1 1 5 1
C h a n g e o f s i g n a t t h e i n p u t
Fig. 9-143 Function of PHINT3 with sign reversal of the input value at C1150 = 2
z
The FB integrates speed or velocity values at PHINT3-IN to a phase (distance).
z PHINT3-OUT outputs the count of the bipolar integrator.
A positive value at PHINT3-IN increments the integrator (count is increased).
A negative value at PHINT3-IN decrements the integrator (count is reduced).
z If the counter content exceeds the value of (+) C1151
the value of C1151 is subtracted from the counter content,
switches PHINT3-STATUS = HIGH for 1 ms.
z If the counter content falls below the value of () C1151
the value of C1151 is added to the counter content,
switches PHINT3-STATUS = HIGH for 1 ms.

Table of Contents