Function library
Function blocks
9.2.63 Storage block (STORE)
9-205
L
EDSVS9332S-D11 EN 3.0
Name LenzeListCFGDIS formatDISType
STORE1-ACT ph - - - - - Outputs the currently integrated value
STORE1-PH1 ph - - - - - Outputs the last value stored by X5/E5
STORE1-PH2 ph - - - - - Outputs the last but one value stored by
X5/E5
STORE1-PHDIFF ph - - - - - Outputs the difference of STORE1-PH1 and
STORE1-PH2
STORE1-TP-INH d - - - - - HIGH = triggering via TP input E5 has been
done. For another triggering a positive edge
must be activated at the input
STORE1-ENTP.
C 1 2 2 3 / 1
S T O R E 2 - R E S E T
C 1 2 2 0 / 1
C 1 2 2 3 / 2
S T O R E 2 - E N T P
C 1 2 2 0 / 2
> 1
_
R
D
1
1
0
T P E i n g a n g E 4
0
R e g 1
R
C
R e g 2
R
C
S T O R E 2 - P H 1
S T O R E 2 - P H 2
S T O R E 2 - A C T
S T O R E 2 - T P - I N H
S T O R E 2
M C T R L - P H I - A C T
Fig. 9-161 Storage block (STORE2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
STORE2-RESET d C1223/1 bin C1220/1 2 1000 HIGH = resets all functions
STORE2-ENTP d C1223/2 bin C1220/2 2 1000 HIGH = enables the triggering via the
TP input E4 free
STORE2-ACT ph - - - - - Outputs the currently integrated value
STORE2-PH1 ph - - - - - Outputs the last value stored by X5/E5
STORE2-PH2 ph - - - - - Outputs the last but one value stored by
X5/E5
STORE2-TP-INH d - - - - - HIGH = triggering via TP input E4 has been
done. For another triggering a positive edge
must be activated at the input
STORE1-ENTP.
Function
z STORE1 control via TP input E5
z Storing STORE1 phase signal
z Storing STORE2 phase signal