EasyManua.ls Logo

Lenze EVS 9300 series - Page 331

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
Function blocks
9.2.63 Storage block (STORE)
9-205
L
EDSVS9332S-D11 EN 3.0
Name LenzeListCFGDIS formatDISType
STORE1-ACT ph - - - - - Outputs the currently integrated value
STORE1-PH1 ph - - - - - Outputs the last value stored by X5/E5
STORE1-PH2 ph - - - - - Outputs the last but one value stored by
X5/E5
STORE1-PHDIFF ph - - - - - Outputs the difference of STORE1-PH1 and
STORE1-PH2
STORE1-TP-INH d - - - - - HIGH = triggering via TP input E5 has been
done. For another triggering a positive edge
must be activated at the input
STORE1-ENTP.
C 1 2 2 3 / 1
S T O R E 2 - R E S E T
C 1 2 2 0 / 1
C 1 2 2 3 / 2
S T O R E 2 - E N T P
C 1 2 2 0 / 2
> 1
_
R
D
1
1
0
T P E i n g a n g E 4
0
R e g 1
R
C
R e g 2
R
C
S T O R E 2 - P H 1
S T O R E 2 - P H 2
S T O R E 2 - A C T
S T O R E 2 - T P - I N H
S T O R E 2
M C T R L - P H I - A C T
Fig. 9-161 Storage block (STORE2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
STORE2-RESET d C1223/1 bin C1220/1 2 1000 HIGH = resets all functions
STORE2-ENTP d C1223/2 bin C1220/2 2 1000 HIGH = enables the triggering via the
TP input E4 free
STORE2-ACT ph - - - - - Outputs the currently integrated value
STORE2-PH1 ph - - - - - Outputs the last value stored by X5/E5
STORE2-PH2 ph - - - - - Outputs the last but one value stored by
X5/E5
STORE2-TP-INH d - - - - - HIGH = triggering via TP input E4 has been
done. For another triggering a positive edge
must be activated at the input
STORE1-ENTP.
Function
z STORE1 control via TP input E5
z Storing STORE1 phase signal
z Storing STORE2 phase signal

Table of Contents

Related product manuals