Function library
Code table
9-267
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0404
-199.99 {0.01 %} 199.99
AIN1
1 (C0402)
Input signals
2 (C0403)
C0405 OUT -199.99 199.99 AIN2
Output signal display
[C0407] OFFSET
19503
FCODE-26/2 →Selection list 1 AIN2
Offset configuration
[C0408] GAIN
19505
FCODE-27/2 →Selection list 1 AIN2
Gain configuration
C0409
-199.99 {0.01 %} 199.99
AIN2
1 (C0407)
Input signal display
2 (C0408)
[C0416] RESOLVER ADJ 0 0 {1} 99999999 Correction of resolver error
For Lenze motors:
Read resolver error from the nameplate
[C0420] ENCODER CONST 512 1 {1 inc/rev} 8192 Encoder input X8/X9
Encoder constant in increments per revolution
[C0421] ENC VOLTAGE 5.00 5.00 {0.1V} 8.00 Encoder voltage supply
Adjust supply voltage for the encoder used
CAUTION:
incorrect input may destroy the encoder
C0425 DFIN CONST 3 0
1
2
3
4
5
6
256 inc/rev
512 inc/rev
1024 inc/rev
2048 inc/rev
4096 inc/rev
8192 inc/rev
16384 inc/rev
DFIN
Increment of the digital frequency input
C0426 DFIN-OUT -32767 {1 rpm} 32767 Output signal of DFIN
C0427 DFIN FUNCTION 0 0
1
2
2 phases
A pulse / B dir
Pulse A or B
DFIN
Selection of master frequency signal
C0429 TP5 DELAY 0 -32767 {1 inc} 32767 Dead time compensation for the TP function of
DFSET and DFRFG
[C0431] IN 5001 MCTRL-NACT →Selection list 1 AOUT1
Input signal configuration
[C0432] OFFSET 19512 FCODE-109/1 →Selection list 1 AOUT1
Offset setting
[C0433] GAIN 19510 FCODE-108/1 →Selection list 1 AOUT1
Gain setting
C0434
-199.99 {0.01 %} 199.99
1 (C0431)
2 (C0432)
3 (C0433)
[C0436] IN 5002 MCTRL-MSET2 →Selection list 1 AOUT2
Input signal configuration
[C0437] OFFSET 19513 FCODE-109/2 →Selection list 1 AOUT2
Offset setting
[C0438] GAIN 19511 FCODE-108/2 →Selection list 1 AOUT2
Gain setting
C0439
-199.99 {0.01 %} 199.99
1 (C0436)
2 (C0437)
3 (C0438)
[C0440] STATE-BUS 1000 FIXED0 → Selection list 2 Configuration - state bus X5/ST
C0441 (C0440)