Function library
Code table
9-279
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0750 VP DENOM 16 1
2
4
8
16
34
64
128
256
512
1024
2048
4096
8192
16384
Vp = 1
Vp = 1/2
Vp = 1/4
Vp = 1/8
Vp = 1/16
Vp = 1/32
Vp = 1/64
Vp = 1/128
Vp = 1/256
Vp = 1/512
Vp = 1/1024
Vp = 1/2048
Vp = 1/4096
Vp = 1/8192
Vp = 1/16384
DFRFG1
Denominator - position controller gain
C0751 DFRFG1 TIR 1.000 0.001 {0.001 s} 999.900 DFRFG1
Tir (acceleration time)
C0752 MAX SPEED 3000 1 {1 rpm} 16000 DFRFG1
Max. speed (here: maximum make-up speed)
C0753 DFRFG1 QSP 0.000 0.000 {0.001 s} 999.900 DFRFG1
Deceleration time when activating the
deceleration ramp
C0754 PH ERROR 2
.
10
9
10 {1} 2
.
10
9
DFRFG1
Following error
1 rev. = 65535 inc
C0755 SYN WINDOW 100 0 {1 inc} 65535 DFRFG1
Synchronisation window
C0756 OFFSET 0 -1
.
10
9
{1 inc} 1
.
10
9
DFRFG1
offset
C0757 FUNCTION 0 0
1
No TP start
With TP start
DFRFG1
Function selection
[C0758] IN 1000 FIXEDPHI-0 Selection list 4 DFRFG1
Input signal configuration
[C0759] QSP 1000 FIXED0 Selection list 2 DFRFG1
Triggering QSP
[C0760] STOP 1000 FIXED0 Selection list 2 DFRFG1
Ramp function generator stop
[C0761] RESET 1000 FIXED0 Selection list 2 DFRFG1
Reset integrators
C0764
1 (C0759)
2 (C0760)
3 (C0761)
C0765 (C0758) -32767 {1 rpm} 32767
C0766 SPEED DIR 1 1
2
3
Direction of rotation cw/ccw (R/L)
Direction of rotation cw (to the right)
Direction of rotation ccw (to the left)
DFRFG1
Selecting direction of rotation
[C0770] D 1000 FIXED0 Selection list 2 FLIP1
Configuration - digital input signal
[C0771] CLK 1000 FIXED0 Selection list 2 FLIP1
Configuration - digital input signal
[C0772] CLR 1000 FIXED0 Selection list 2 FLIP1
Configuration - digital input signal
C0773
1 (C0770)
2 (C0771)
3 (C0772)

Table of Contents