Function library
Code table
9-280
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0775] D 1000 FIXED0 → Selection list 2 FLIP2
Configuration - digital input signal
[C0776] CLK 1000 FIXED0 → Selection list 2 FLIP2
Configuration - digital input signal
[C0777] CLR 1000 FIXED0 → Selection list 2 FLIP2
Configuration - digital input signal
C0778
1 (C0775)
2 (C0776)
3 (C0777)
[C0780] N 50 AIN1-OUT →Selection list 1 NSET
Configuration - main setpoint input
[C0781] N-INV 10251 R/L/Q-R/L → Selection list 2 NSET
Configuration - main setpoint inversion
[C0782] NADD 5650 ASW1-OUT →Selection list 1 NSET
Configuration - additional setpoint input
[C0783] NADD-INV 1000 FIXED0 → Selection list 2 NSET
Configuration - additional setpoint inversion
[C0784] CINH-VAL 5001 MCTRL-NACT →Selection list 1 NSET
Configuration - output signal with controller
inhibited
[C0785] SET 5000 MCTRL-NSET2 →Selection list 1 NSET
Configuration - ramp function generator
[C0786] LOAD 5001 MCTRL-QSP-OUT → Selection list 2 NSET
Digital input (load ramp function generator)
[C0787] → Selection list 2
NSET
1 JOG*1 53 DIGIN3
Configuration - JOG selection and JOG
2 JOG*2 1000 FIXED0
ac
iva
ion
3 JOG*4 1000 FIXED0
na
y
n
e
p
e
a
on
4 JOG*8 1000 FIXED0
[C0788] → Selection list 2
NSET
1 TI*1 1000 FIXED0
Configuration - Ti selection and Ti activation
2 TI*2 1000 FIXED0
Binary interpretation
3 TI*4 1000 FIXED0
Ti
and Ti
pai
sa
eiden
ical
4 TI*8 1000 FIXED0
[C0789] RFG-0 1000 FIXED0 → Selection list 2 NSET
Configuration - digital input (ramp function
generator 0)
[C0790] RFG-STOP 1000 FIXED0 → Selection list 2 NSET
Configuration - digital input (ramp function
generator stop)
C0798
-199.99 {0.01 %} 199.99
NSET
1 CINH-VAL
Display of analog input signals
2 SET