EasyManua.ls Logo

Lenze EVS 9300 series - Page 414

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
Code table
9-288
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0940 NUMERATOR 1 -32767 {1} 32767 CONV1
Numerator
C0941 DENOMINATOR 1 1 {1} 32767 CONV1
Denominator
[C0942] CONV1-IN 1000 FIXED0% Selection list 1 CONV1
Configuration - analog input
C0943 (C0942) -199.99 {0.01 % } 199.99
C0945 NUMERATOR 1 -32767 {1} 32767 CONV2
Numerator
C0946 DENOMINATOR 1 1 {1} 32767 CONV2
Denominator
[C0947] IN 1000 FIXED0% Selection list 1 CONV2
Configuration - analog input
C0948 (C0947) -199.99 {0.01 % } 199.99
C0950 NUMERATOR 1 -32767 {1} 32767 CONV3
Numerator
C0951 DENOMINATOR 1 1 {1} 32767 CONV3
Denominator
[C0952] IN 1000 FIXEDPHI-0 Selection list 4 CONV3
Configuration - analog input
C0953 (C0952) -32767 {1 rpm} 32767
C0955 NUMERATOR 1 -32767 {1} 32767 CONV4
Numerator
C0956 DENOMINATOR 1 1 {1} 32767 CONV4
Denominator
[C0957] IN 1000 FIXEDPHI-0 Selection list 4 CONV4
Configuration - analog input
C0958 (C0957) -32767 {1 rpm} 32767
C0960 FUNCTION 1 1
2
3
Characteristic 1
Characteristic 2
Characteristic 3
CURVE1
Selection of the characteristic function
C0961 Y0 0.00 0.00 {0.01 %} 199.99 CURVE1
Configuration - base point
Ordinate of the p air (x = 0 % / y0)
C0962 Y1 50.00 0.00 {0.01 %} 199.99 CURVE1
Configuration - base point
Ordinate of the value pair (x1 / y1)
C0963 Y2 75.00 0.00 {0.01 %} 199.99 CURVE1
Configuration - base point
Ordinate of the value pair (x2 / y2)
C0964 Y100 100.00 0.00 {0.01 %} 199.99 CURVE1
Configuration - base point
Ordinate of the value pair (x 100 % / y100)
C0965 X1 50.00 0.01 {0.01 %} 99.99 CURVE1
Configuration - base point
Abscissa of the pair (x1 / y1)
C0966 X2 75.00 0.01 {0.01 %} 99.99 CURVE1
Configuration - base point
Abscissa of the pair (x2 / y2)
[C0967] IN 1000 FIXED0% Selection list 1 CURVE1
Configuration - analog input
C0968 (C0967) -199.99 {0.01 % } 199.99
[C0970] N-SET 1000 FIXED0% Selection list 1 MFAIL
Configuration - speed input (setpoint path)
[C0971] FAUL T 1000 FIXED0 Selection list 2 MFAIL
Configuration - digital input (activating the
mains failure control)

Table of Contents

Related product manuals