RMON History
Use the RMON History Configuration page for configurations.
PATH
Configuration \ Security \ Switch \ RMON \ History
Figure 26: RMON History Configuration
PARAMETERS
These parameters are displayed:
Delete Check to delete the entry after the next save.
ID Indicates the index of the entry. The range is from 1 to 65,535.
Data Source Indicates the port ID which wants to be monitored. If in stacking switch, the
value must add 1000*(switch ID-1), for example, if the port is switch 3 port 5, the value is
2005.
Interval Indicates the interval in seconds for sampling the history statistics data. The
range is from 1 to 3600, default value is 1800 seconds.
Buckets Indicates the maximum data entries associated this History control entry stored
in RMON. The range is from 1 to 3600, default value is 50.
Buckets Granted The number of data shall be saved in the RMON.
WEB INTERFACE
To configure RMON History table:
1. Click Configuration, Security, Switch, RMON, History.
2. Click Add New Entry to create a new entry. The entry index key is ID.
3. Specify the ID, Data Source, interval settings.
4. Click Save.