Diagnostic aids 3-29
7500-XXX
4. Make required adjustments and touch Submit.
Note: All reference to Side Registration in the graphic below, refers to the left side edge.
5. Turn the machine off and then back on in order to make a copy.
6. Using the registration test original page, make a copy using the flatbed scanner and the ADF side 1 and
ADF side 2 to verify adjustments for accuracy.
7. If further adjustments are required, reenter Diagnostic Menu and repeat items 2 through 6 as needed.
The panel displays the following settings:
1
Each increment of adjustment corresponds to:
1 scan at 300 dpi for the Lead Margin setting or
1 pel at 300 dpi for each Side Margin setting
2
Decreasing the registration value moves the text toward the left side edge of the page; increasing the
registration value moves the text away from the left side edge of the page. The entire image moves left or right
on the page; therefore, no compression or expansion of the image occurs to preserve the left side margin.
Margin Setting Range
1
Units
Flatbed Side Registration
2
0 - 240 1/300 inch
Flatbed Lead Registration
3
16 -184 1/300 inch
ADF Side1 Side Registration
4
0 - 240 1/300 inch
ADF Side1 Lead Registration
5
0 - 214 1/300 inch
ADF Side2 Side Registration
4
0 - 240 1/300 inch
ADF Side2 Lead Registration
5
0 - 214 1/300 inch