Repair information 4-65
7500-XXX
MPF fold down tray assembly removal
1. Remove the MPF rear cover. See “MPF rear cover removal” on page 4-58.
2. Remove the MPF feed unit assembly. See “MPF feed unit assembly removal” on page 4-54.
3. Remove the MPF upper frame. See “MPF media out actuator and upper frame removal” on
page 4-55.
4. Remove the pickup spring (A) from the idler gear bracket assembly (B).
Note: Leave the pickup spring (A) attached to the MPF feed drive gear pickup (C).
5. Remove three screws securing the idler gear bracket assembly (B) to the MPF feed unit assembly.
6. Remove the idler gear bracket assembly (B).
7. Remove the green ground wire (D) from the idler gear bracket assembly (B).
8. Remove the green (D) ground wire from the clamp.
Hook
Rear
A
C
B
D