NTP-016: System Turnup 363-206-285
Page 2 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
4.
NOTE:
As additional circuit packs are installed, office alarms may be
activated, accompanied by flashing FAULT LEDs on some of
the circuit packs. This is a normal condition at this stage of
the procedure. You can momentarily depress the ACO/TST
pushbutton to retire office alarms.
NOTE:
BBF4 TG3 circuit packs cannot be mixed with
BBF2/BBF2B/BBF2C TGS circuit packs in the same
DDM-2000 OC-3 shelf.
NOTE:
To avoid timing alarms before the end-to-end OC-3 system
has been established, the TGS/TG3 option switches must be
temporarily
set to
free running
if either of the following is
true:
• DS1 external timing is specified but the DS1 timing
reference is not yet available.
• Line timing mode is specified but the OLIUs will be
optically looped back at the shelf.
When the DS1 external timing references become available
or when the end-to-end system is established, the timing
mode must be changed to the specified timing mode. If
external timing is the specified timing mode and external
timing is available to the shelf, the timing mode may be set
for external timing.
DLP-503Install TGS/TG3 timing circuit packs.
DLP-503

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals