Page #1680 background image
NTP-039: Circuit Order 363-206-285
Page 28 of 32 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
Figure 21 – DDM-2000 OC-3 Drop or Add/Drop Network to Ring Upgrade
DLP-53246. At Node 4 (RTn-1), locally download TARP Release 13 or later
software.
47. Reinstall TGS/TG3 circuit pack into TIMING slot 1. Use the
switch-sync:s=circuitpack,pri=reset command to
reset the manual protection switch.
48. At Node 4 (RTn-1), use the ent-crs-vt1: command or
ent-crs-sts1: command to set up all main-to-main
pass-through cross-connections associated with all remaining
STS/VT timeslots that are terminated on other nodes of the ring.