DLP-507: Detailed Level Procedure 363-206-285
Page 4 of 4 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
9.
NOTE:
Since cross-connections associated with BBG19 DS3 circuit packs are
non-path-switched locked cross-connections, a BBG19 DS3 circuit pack
installed in FUNCTION UNITS group slot ()1at one terminating node is
associated with the BBG19 DS3 circuit pack in FUNCTION UNITS group
slot ()2(P)at the other terminating node.
NOTE:
If response is not correct in the following procedures, replace the BBG19
DS3 circuit pack.
Seat BBG19 DS3 circuit packs in FUNCTION UNITS group slots A(), B()or
C()being equipped.
Response: FAULT LED on the BBG19 DS3 lights for about 20
seconds then goes off. ACTIVE LED lights on BBG19
DS3 circuit pack.
10. STOP. YOU HAVE COMPLETED THIS PROCEDURE.