DLP-512: Detailed Level Procedure 363-206-285
Page 8 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Cross-connection type twoway twoway ent-crs-sts3c
Expected STS-1 path
trace message 62 characters see command pgs. set-trace-sts1
Outgoing STS-1 path
trace message 62 characters see command pgs. set-trace-sts1
Notes:
1. Default means factory default (the CIT prompts display current provisioned values).
2. To view the current values, precede these commands with rtrv- instead of set-
†Parameter can be set for each port.
‡ AUTO means the port or channel is ready to be automatically provisioned via signal detection.
§ noOverride means read and use switch settings on circuit pack.
¶ Track means the source for iming will be selected from the active received OC-3 line specified.
** This command is available to privileged users only.
††Rings.
‡‡ Setting this parameter also affects DS1 output source and DS1 sync output mode. See set-sync
command in Section 11, "Commands and Reports".
¶¶ This parameter is not applicable to the BBG20 TMUX circuit pack.
*** Parameters can be set for each channel.
†††Ring releases. Requires 22D-U/22G-U/22G2-U/22G3-U OLIUs.
‡‡‡ Ring releases.
§§§ With 24G-U/24H-U/29G-U/29H-U OLIUsinMAINslots.
¶¶¶ This parameter is only applicable to the BBG20 TMUX circuit pack.
Table A – DDM-2000 OC-3 Parameters Provisionable Via the CIT (Contd)
Parameter Range
Default
(Note1) Command(Note2)