363-206-285 Detailed Level Procedure: DLP-523
Issue 2, February 2000 Page 2 of 30
DDM-2000 OC-3 MULTIPLEXER
BBG8/BBG8B SYSCTL
2. Refer to DLP-501 to replace the SYSCTL.
3. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
BBG2/BBG2B MXRVO
4.
!
CAUTION:
To prevent errors, use the
sw-fn:address:pri=manual
command to
switch service to the standby slot before removing the
MXRVO
circuit
pack being replaced.
There are no options to be set on the BBG2/BBG2B MXRVO circuit pack.
Remove old MXRVO and install replacement MXRVO.
Response: FAULT LED on the MXRVO lights for about 13 seconds
and then goes off.
5. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
BBF3/BBF3B DS1PM Step 34
BBF5 JMPR Step 39
BBG6 STS1E Step 41
BBF8 HDSL Step 47
BBF6 T1EXT Step 51
BBF9/BBF10 LAN Step 55
Table A – Circuit Pack Replacement (Contd)
Circuit Pack Step
DLP-501

Table of Contents