DLP-523: Detailed Level Procedure 363-206-285
Page 3 of 30 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
BBG9 OHCTL
6.
NOTE:
For TARP Release 13 and later applications, the OHCTL must be a
BBG9 OHCTL.
There are no options to be set on the BBG9 OHCTL.
NOTE:
If no software is installed in the OHCTL or if the software is not
compatible with the software in the SYSCTL, the letter d will be displayed
in the FE ID display on the SYSCTL. If this occurs, you must find circuit
packs with compatible software or install new software in both the
OHCTL and SYSCTL [DLP-532].
Install OHCTL into AUXCTL slot. (If software is not loaded or is incompatible,
load new software using DLP-532).
7. STOP. YOU HAVE COMPLETED THIS PROCEDURE.