363-206-285 Detailed Level Procedure: DLP-523
Issue 2, February 2000 Page 22 of 30
DDM-2000 OC-3 MULTIPLEXER
37.
!
CAUTION:
When a
DS1/DS1PM
circuit pack is switched to protection, removal of
any other
DS1/DS1PM
circuit pack or
177A
Retainer Card in the same
LOW SPEED GROUP
will result in a loss of service to the protected
DS1/DS1PM
circuit pack and the removed
DS1/DS1PM
circuit pack.
NOTE:
If a signal has previously been applied to the original DS1/DS1PM circuit
pack, the FAULT lamp will flash when the new DS1/DS1PM circuit pack is
installed until the signal tests good.
NOTE:
A DS1PM circuit pack must be replaced with the same type circuit pack to
retain the proper feature applications. Also, if protection is required and
DS1PM circuit packs are installed in the service slots, the protection
circuit pack must be a DS1PM circuit pack. A CP not allowed
(eqpt) alarm will be generated if a DS1PM circuitpackisinstalledina
service slot with no DS1PM circuit pack in the protection slot.
Remove old DS1/DS1PM circuit pack and install replacement DS1/DS1PM
circuit pack.
Response: FAULT LED on the DS1/DS1PM circuit pack may light
(flash) for up to 40 seconds and then goes off.
38. STOP. YOU HAVE COMPLETED THIS PROCEDURE.