363-206-285 Detailed Level Procedure: DLP-526
Issue 2, February 2000 Page 2 of 8
DDM-2000 OC-3 MULTIPLEXER
Verify the generic parameters of the modem are set to the following:
• 300, 1200, 2400, 4800, 9600, or 19,200 baud
The Lucent Technologies 4024 and Lucent Technologies 2224 CEO
modems support 1200 and 2400 baud rates. The Lucent Technologies
2296 modem supports 4800 or 9600 baud rates.
• Full duplex
• 8 data bits
• No parity bits
•1startbit
• 1 stop bit
• No flow control
• Transparent data mode - ON (Required for software download on some
modems.)
• Direct operating mode - ON (Required for software download on some
modems.).
2. Are you at the DDM-2000 location or remote CIT location?
If DDM-2000 LOCATION, continue with Step 3.
If REMOTE CIT LOCATION, proceed to Step 7.