363-206-285 Detailed Level Procedure: DLP-564
Issue 2, February 2000 Page 2 of 2
DDM-2000 OC-3 MULTIPLEXER
Seat HDSL circuit pack in required slot of LOW SPEED group being equipped.
Response: FAULT LED on HDSL circuit pack lights and may remain
lighted for about 40 seconds and then goes off.
3. Repeat this procedure from Step 1 for each service HDSL circuit pack being
installed.
4.
NOTE:
One protection HDSL circuit pack may be installed in slot 8(P) of each
LOW SPEED group being equipped.
If required, refer to Figure 1 and Table A and set option switches on protection
HDSL circuit pack.
5. If required, install protection HDSL circuit pack into slot 8(P) of low-speed
group being equipped.
6. Install 177A Retainer Cards into all unequipped service DS1 LOW SPEED
slots.
7. STOP. YOU HAVE COMPLETED THIS PROCEDURE.