DLP-566: Detailed Level Procedure 363-206-285
Page 3 of 4 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
8.
NOTE:
The checkpgm command may take up to 25 minutes to complete.
Execute the command checkpgm to check the version number of the program
you are installing. If using floppy disks, insert each diskette when prompted.
Response: PC has DDM-2000 program version a.b.c
9.
NOTE:
The shelf rear access CIT port is configured for a modem. A null modem
is required to use this port with the PC.
NOTE:
The cable from the CIT port on the DDM-2000 must be connected to the
COM (COM1 or COM2) RS-232 port of the PC. If a "P"or"d" is displayed
in the FE ID display, the PC must be connected to the front CIT port.
Connect PC to CIT port by connecting one end of an RS-232 cable to the
COM( ) port of the PC and the other end of the cable to the front or rear
DDM-2000 CIT port.
10. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
approx. 15 min. if using hard drive
approx. 25 min. if using floppy drive

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals