Grove Published 02-21-2019, Control # 611-05 3-107
TMS9000-2 OPERATOR MANUAL OPERATING CONTROLS AND INDICATORS
3
REMOTE CONTROL OPERATION
Scope
This section specifies system requirements and theory of
operation for the Hand-Held, Wireless Remote Control
available for the TMS9000-2.
This section does not contain:
Operating instructions for the controls on the crane
Setup and installation instructions
Before using the remote control, the operator shall read and
become thoroughly familiar with the instructions in the
TMS9000-2 Operator Manual.
System Overview
The remote control has been provided to operate the
following crane functions during crane set-up only:
Superstructure horn
Engine start/stop and throttle control
Outrigger beams and jacks
Hoists (aux and main hoist)
Boom lift
Swing (swing) and 360° swing lock
Luffing boom extension
Boom Extension stowage actuators
Counterweight system cylinders
The remote control is not intended to operate crane functions
during normal crane operation.
When the remote control is used during crane set-up, the
RCL is disabled and associated lockouts and limiters are not
functional, to include:
Anti-two block
Hoist minimum wrap
Carrier avoidance
WARNING
Tipping/Overload Hazard!
RCL lockouts and limiters are not functional when remote
control is used.
When operating functions from remote control, operator
must be positioned to see crane movement.
Read the Operator Manual.

Table of Contents