Grove Published 02-21-2019, Control # 611-05 3-115
TMS9000-2 OPERATOR MANUAL OPERATING CONTROLS AND INDICATORS
3
Table 3-5 Engine Start/Stop/Throttle Function Screen
Engine Start/Stop/Throttle
See Figure 3-173
Starting/Stopping Engine
1. Press the engine button on the remote control
ONCE. The engine screen (1) appears.
2. To START the engine, hold down either enable button
and the right motion button at the same time. Release
both buttons as soon as the engine starts.
If a condition exists that prevents the engine from being
started, information will be provided in the display.
Common conditions that prevent the engine from being
started are: the carrier transmission is in gear or the
carrier park brake is released.
3. To STOP the engine, hold down either enable button
and the left motion button at the same time. Release
both buttons once the engine stops.
Changing Engine Speed
1. Press the engine button on the remote control
ONCE if already at the engine screen, or TWICE if at the
main screen. The throttle screen (4) appears.
2. To INCREASE engine speed, hold down either enable
button and the right motion button at the same time.
3. To DECREASE engine speed, hold down either enable
button and the left motion button at the same time.
The engine’s speed is shown in the RPM screen (8).
When the remote control is on, engine speed cannot be
controlled from the crane.
Exiting Start/Stop/Throttle Screen
To exit this screen, press the ESC button on the remote
control. The main screen appears.
Item Indicator Name Description
1
Engine (start/stop)
Function
1a - Yellow = engine cannot be started or stopped due to a crane fault
1b - Green = engine can be started or stopped
2 Stop Engine
2a - Blue = engine cannot be stopped until either enable button is held down
2b - Green = engine can be stopped with left motion button
3 Start Engine
3a - Blue = engine cannot be started until either enable button is held down
3b - Green = engine can be started with right motion button
4
Engine RPM
Function
4a - Yellow = engine RPM cannot be changed due to a crane fault
4b - Green = engine RPM can be changed
5 Decrease RPM
5a - White = engine RPM cannot be decreased until either enable button is held down
5b - Green = engine RPM can be decreased with left motion button
6 Increase RPM
6a - White = engine RPM cannot be increased until either enable button is held down
6b - Green = engine RPM can be increased with right motion button
7
Enable Button
Status
7a - White = both enable buttons released (operation disabled)
7b - Green = either enable button held down (operation enabled)
8 RPM Screen Shows the engine speed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS9000-2 Series and is the answer not in the manual?

Manitowoc Grove TMS9000-2 Series Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS9000-2 Series
CategoryConstruction Equipment
LanguageEnglish

Related product manuals