SAFETY INFORMATION TMS9000-2 OPERATOR MANUAL
2-44 Published 02-21-2019, Control # 611-05
The following checklist includes all features that can be
found on Grove cranes. Your crane may not have some
features.
Overload less than 25%
1
Sheaves Inspect all for damage.
2
Luffing
Mechanism/
Cylinder
Inspect for damage/leaks.
3
Collar-wear
pads
Inspect all for damage.
Overload from 25% to 49%
1
Sheaves Inspect all for damage.
2
Luffing
Mechanism/
Cylinder
Inspect for damage/leaks.
3
Collar-wear
pads
Inspect all for damage.
4
Collar-welds Inspect all for cracks.
5
Telescopic
Sections
Inspect for bent or twisted sections. Check the boom for
straightness.
6
Lift Cylinder
Head Area
Inspect for bends or cracked welds.
7
Turret-Base
Section
Inspect for cracked welds.
8
Locking Area
(Pin Booms)
Inspect for elongated holes.
9
Welds Inspect for cracks.
10
Paint
Inspect for cracked paint which could indicate twisted,
stretched, or compressed members.