E - 4 VM600 networking manual MAVM600-NET/E
Edition 9 - February 2018
APPENDIX E: SYMBOL NAMES
MPC
Basic & Advanced Functions
RLY1A - 0 0 RLY1 is in Alarm state (RLY1 LED is red)
RLY1ERR - 0 0 RLY1 is in Error state (RLY1 LED is Yellow blinking)
RLY2A - 0 0 RLY2 is in Alarm state (RLY2 LED is red)
RLY2ERR - 0 0 RLY2 is in Error state (RLY2 LED is Yellow blinking)
RLY3A - 0 0 RLY3 is in Alarm state (RLY3 LED is red)
RLY3ERR - 0 0 RLY3 is in Error state (RLY3 LED is Yellow blinking)
RLY4A - 0 0 RLY4 is in Alarm state (RLY4 LED is red)
RLY4ERR - 0 0 RLY4 is in Error state (RLY4 LED is Yellow blinking)
RLY5A - 0 0 RLY5 is in Alarm state (RLY5 LED is red)
RLY5ERR - 0 0 RLY5 is in Error state (RLY5 LED is Yellow blinking)
RLY6A - 0 0 RLY6 is in Alarm state (RLY6 LED is red)
RLY6ERR - 0 0 RLY6 is in Error state (RLY6 LED is Yellow blinking)
RLY7A - 0 0 RLY7 is in Alarm state (RLY7 LED is red)
RLY7ERR - 0 0 RLY7 is in Error state (RLY7 LED is Yellow blinking)
RLY8A - 0 0 RLY8 is in Alarm state (RLY8 LED is red)
RLY8ERR - 0 0 RLY8 is in Error state (RLY8 LED is Yellow blinking)
DSI1 - 0 0 Discrete Input #1 (‘0’=Open, ‘1’=Short to GND)
DSI2 - 0 0 Discrete Input #2 (‘0’=Open, ‘1’=Short to GND)
DSI3 - 0 0 Discrete Input #3 (‘0’=Open, ‘1’=Short to GND)
DSI4 - 0 0 Discrete Input #4 (‘0’=Open, ‘1’=Short to GND)
AR - 0 0 Alarm Reset (‘0’=Open, ‘1’=Short to GND)
DB - 0 0 Danger Bypass (‘0’=Open, ‘1’=Short to GND)
IRCOK - 0 0 IRC4 Common OK
AMC
Input Channel 1
nCH1A+ Slot n (CH1 A+) 0 0 Input Channel 1 Alarm+
nCH1A- Slot n (CH1 A-) 0 0 Input Channel 1 Alarm-
nCH1D+ Slot n (CH1 D+) 0 0 Input Channel 1 Danger+
nCH1D- Slot n (CH1 D-) 0 0 Input Channel 1 Danger-
nCH1GOKF Slot n (CH1 Global OK Fail) 0 0 Input Channel 1 Global Channel OK Fail
AMC
Input Channel 2
nCH2A+ Slot n (CH2 A+) 0 0 Input Channel 2 Alarm+
nCH2A- Slot n (CH2 A-) 0 0 Input Channel 2 Alarm-
nCH2D+ Slot n (CH2 D+) 0 0 Input Channel 2 Danger+
nCH2D- Slot n (CH2 D-) 0 0 Input Channel 2 Danger-
nCH2GOKF Slot n (CH2 Global OK Fail) 0 0 Input Channel 2 Global Channel OK Fail
AMC
Input Channel 3
nCH3A+ Slot n (CH3 A+) 0 0 Input Channel 3 Alarm+
nCH3A- Slot n (CH3 A-) 0 0 Input Channel 3 Alarm-
nCH3D+ Slot n (CH3 D+) 0 0 Input Channel 3 Danger+
nCH3D- Slot n (CH3 D-) 0 0 Input Channel 3 Danger-
nCH3GOKF Slot n (CH3 Global OK Fail) 0 0 Input Channel 3 Global Channel OK Fail
AMC
Input Channel 4
nCH4A+ Slot n (CH4 A+) 0 0 Input Channel 4 Alarm+
nCH4A- Slot n (CH4 A-) 0 0 Input Channel 4 Alarm-
nCH4D+ Slot n (CH4 D+) 0 0 Input Channel 4 Danger+
nCH4D- Slot n (CH4 D-) 0 0 Input Channel 4 Danger-
nCH4GOKF Slot n (CH4 Global OK Fail) 0 0 Input Channel 4 Global Channel OK Fail
Table E-1: Reserved words (Symbol names)