98 Panel Functions
_________________________________________________________________________________________
_________________________________________________________________________________________
Microplex logiJET TC8 Edition 1.2
Steps to set the Switching Threshold (Sync.Sens.Level) at the printer panel:
Panel display
[ON LINE ]
[Menu Level 1 ]
[Engine ]
[Printspeed ]
[Sync. Menu ]
[Auto.Sens.Adj. ]
[Sync.Sens.Level ]
[Level: 44% 40.0% ]
[Level: 44% 28.0% ]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
Press the NEXT or PREVIOUS key until
[Engine ] is displayed.
Press the ENTER key. This selects the
Engine menu.
Press the NEXT or PREVIOUS key until
[Sync. Menu ] is displayed.
Press the ENTER key. This selects the
Sync menu.
Press the NEXT or PREVIOUS key until
[Sync.Sens.Level ] is displayed.
Press the ENTER key to adjust the
switching threshold of the sensor.
At the right the currently set switching
threshold is displayed. (At the left the
sensor measured contrast value is
displayed.)
Press the NEXT or PREVIOUS key until the
desired switching threshold is displayed.
In this example the switching threshold is
adjusted to 28%.
In addition this new value can be saved as
setup value (using the ENTER key).
After this decision turn the printer ON
LINE again: Press the ONLINE key longer
than 2 seconds.
Sensor measured value
Switching Threshold