– 4.35 –
[Wiring check]
• After the heater has been attached, be sure to check.
• The heater wires may be broken if the selector is not set correctly.
1) Set all the selectors to 110V.(Selector : 130SL/130SPII/160SP x3, 75SPII x2)
Make sure that the resistance between A1 to A4 is the following value.
75SPII : 46 – 53 Ω
130SL/130SPII : 31 – 35 Ω
160SP : 32 – 37 Ω
Make sure that the resistance between A5 to A8 is the following value.
75SPII : 52 – 59 Ω
130SL/130SPII : 22 – 27 Ω
160SP : 18 – 22 Ω
2) Set three selectors to 220V.(Selector : 130SPII/160SP x3, 75SPII x2)
Make sure that the resistance between A1 to A4 is the following value.
75SPII:184 – 213 Ω
130SL/130SPII:122 – 140 Ω
160SP :128 – 147 Ω
Make sure that the resistance between A5 to A8 is the following value.
75SPII : 206 – 237 Ω
130SL/130SPII : 90 – 105 Ω
160SP : 73 – 85 Ω
3) After confirmation, restore the voltage of three selectors to the voltage used previously.
(Selector : 130SL/130SPII/160SP x3, 75SPII x2)