– 4.8 –
4-2-3. Washing a single S-Print head assy
CAUTION
Be sure to wear protection glasses since you may get ink in your eyes.
If the ink sticks to your hand, the skin may be damaged.
Be sure to wash the assy before head replacement.
Water-based transportation liquid (S-46), which is supplied in the head at the time
of shipment, reacts to solvent ink to generate deposit. Therefore, it is necessary to
wash the assy using cleaning liquid for S head replacement (MS cleaning liquid)
before head replacement.
Periodically replace the injection material in the head. The syringe rubber is not
resistant to solvent.
[Parts to be used]
Replacement parts : S-print head assy (M004905)
Head cleaning tool (M005027)
Cleaning fluid for S-head replacement (M005026)
Waste (non-woven paper, etc.)
[How to use cleaning liquid and instruction for head exchange]
When replacing the head, be careful not to put the liquid (cleaning liquid, ink,
transportation liquid and water, etc.) on the head PCB.
If running the liquid on the head PCB, misfiring of large amounts of mist may
cause.
1) Input ID in advance before run the
washing liquid in the head. (to prevent
the cleaning liquid from attaching to the
head PCB when washing and inputting
ID.)
Injection Material

Table of Contents

Other manuals for MIMAKI JV3-160SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV3-160SP and is the answer not in the manual?

MIMAKI JV3-160SP Specifications

General IconGeneral
BrandMIMAKI
ModelJV3-160SP
CategoryPlotter
LanguageEnglish

Related product manuals