EasyManuals Logo

MIMAKI JV3-160SP User Manual

MIMAKI JV3-160SP
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
– 4.31 –
[Precautions]
Confirm the following precautions before replace a heater.
1. Confirm that the heater and the cable protection tube are joined firmly.
Remove the protection tube and makes sure the terminal comes in the center of the
protection tube.
In case silicon adhesive is being used for the cable and the protection tube joint, it is not
necessary to remove the protection tube.
Protection glass tube
Protection gum tube
Terminal
Heater
Cable
2. Write a number for each terminal of a heater.
For a printheater, use the number from 1 to 4, as for a Preheater, use 5 to 8 (75SPII) or 5
to 12 (130SL, 130SPII, 160SP).
Be sure giving
a consecutive number for each terminal of one heater.
Example of Printheater
Mark
the number here

Table of Contents

Other manuals for MIMAKI JV3-160SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV3-160SP and is the answer not in the manual?

MIMAKI JV3-160SP Specifications

General IconGeneral
BrandMIMAKI
ModelJV3-160SP
CategoryPlotter
LanguageEnglish

Related product manuals