EasyManua.ls Logo

MIMAKI JV34-260 - Automatic Maintenance Configuration; Automatic Maintenance Function Settings

MIMAKI JV34-260
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-20
Automatic Maintenance Function
To use this machine comfortably, you can set various maintenances to be performed automatically.
Here, set performing intervals of various automatic maintenances.
You can prevent troubles such as ink clogging by performing automatic maintenance periodically (automatic
maintenance function).
For the auto maintenance functions, the following items can be set:
Setting the Refreshing Intervals
The interval between each operation of ejecting a small amount of ink from the nozzles to prevent nozzle
clogging is set.
1
Select [AUTO MAINT.] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AUTO MAINT.].
2
Press the key.
3
Press the key.
4
Press to set the refreshing interval.
Set value : OFF or 1 to 168 hours
5
Press the key.
6
Press the key several times to end the setting.
The maintenance intervals (default value) differ depending on the ink type you use. For details, refer
to P.7-4 “Maintenance intervals of automatic maintenance function”.
When you perform maintenance manually, after manual maintenance is completed and when time set
with the automatic maintenance function has passed, maintenance starts automatically.
Function name Descriptions
REFRESH
The interval between each refreshing operation is set.
PUMP TUBE WASH
The interval between each PUMP tube washing operation is set.
CLEANING
The interval between each cleaning operation is set.
During the right message is displayed, the operation set in the
auto maintenance function is not carried out. Perform the
operations of P.5-28 if required.
When the power switch on the front of the machine is turned off,
check the waste ink tank.
<LOCAL. 1> [ #01 ]
!WASTE TANK
AUTO MA I NT .
REFRESH < e n t >
AUTO MA I NT .
REFRESH i n t e r v a l =
1 h
AUTO MA I NT .
REFRESH i n t e r v a l = 1
0 h
AUTO MA I NT .
REFRESH < e n t >