5-24
Setting the Head Selection
You can select the head to use for printing.
When one head cannot be used because nozzle clogging has not been solved etc., you can set that the head
with nozzle clogging will not be used.
1
Select [HEAD SELECT] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [HEAD SELECT].
2
Press the key.
3
Press to select a head to use.
• Set Value : 12 (Use both heads.)
1_ (Use Head 1 only.)
_2 (Use Head 2 only.)
4
Press the key.
5
Press the key several times to end the setting.
• The scope of head selection is from printing (including test printing) to flushing. Filling function etc.
targets all heads.
• When you print with only one head, the printing speed is dimidiated compared with when printing with
two heads.