7-4
Setting orders depending on ink type
The setting value and the setting orders of the ink cartridges differ depending on the ink type you use.
Rough standard of heater temperature setting value
When you use solvent ink, the optimal values of Pre heater/ Print heater/ Post heater differ depending on the
ink type you use.
Setting orders of ink cartridges
The orders of ink cartridges set in the ink station differ depending on the ink set you use.
Maintenance intervals of automatic maintenance function
The default values of the automatic maintenance functions set in the automatic function differ depending on the
ink type you use.
Type of ink SS21 ink
Type of media All medias
Set of the Pre-heater 35°C
Set of the Print-heater 35°C
Set of the Post-heater 50°C
• Adjust it to suitable temperature depending on the media condition.
• When aqueous-color ink is used, no reference for the temperature set is required.
• Set the ink cartridge according to the cartridge label under the ink station.
Function name
Default value Default value
SS21 ink Sb52 ink
REFRESH maintenance intervals
4h 4h
PUMP TUBE WASH maintenance intervals
48h 48h
CLEANING maintenance intervals
OFF OFF