Troubleshooting
6-3
1
1
1
1
6
Troubleshooting
Media get jammed / media is soiled
Media jamming or stained media is considered to be due to the use of an unsuitable media or improper setting
of media.
[HEAT] or [CONSTANT] LED does not light up
Check the basic operation.
Is a recommended media used ? Use recommended media.
Is the media not curled or bent ends ? Avoid using any media with curls or bent ends.
Yes
Is the media hanging down along the platen
?
Use a take-up device or re-load the media on
the machine. ( P.2-6 , P.2-25)
Is the power to the machine ON ? Turn on the power to the machine. ( P.2-4)
Yes
Is the heater temperature setting effective ? Set the heater temperature. ( P.3-8)