Maintaining the Capping Station
5-7
1
1
1
5
Routine Maintenance
Replacing the wiper
The wiper is consumable.When the display indicates that it is necessary to
replace the wiper, immediately replace the wiper with a new one.
Also, wipe ink sticking to the lower surface of the slider off.
1
Press the key in LOCAL.
2
Press to select [WIPER REPLACE].
3
Press the key.
• The carriage moves onto the platen.
4
Open the front cover then remove the wiper.
• Pull out the wiper by holding the protrusions at its both ends.
5
Insert a new wiper.
• Insert a new wiper by holding its both ends.
6
Close the front cover then press the key.
• After its initial operation, the machine returns to LOCAL.
• A cleaning wiper is an option.Buy one through the dealer in your region or at our service office.
• Do not select [WIPER REPLACE] at any time other than when the wiper is replaced.Once it is
selected, the counter that counts the number of times the wiper is used is reset.
• Until the replacement work is completed, [COMPLETED: ent] is displayed on the screen.
After the work up to the Step 5 is completed and you close the front cover, press the
key. If you press the key before the replacement work is completed,
the carriage returns to the original position.