Automatic Maintenance Function
5-22
Setting the Cleaning Intervals
This is a function operated instead of the PUMP tube washing when the cleaning solution for maintenance has
been used up.
The cleaning type and the interval between each cleaning operation are set.
1
Select [AUTO MAINT.] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AUTO MAINT.].
(4) Press the key.
2
Press to select [CLEANING].
3
Press the key.
4
Press to set the interval between each
cleaning operation.
Set value : OFF or 1 to 168 hours
5
Press the key.
The cleaning type selection screen appears.
6
Press to select a cleaning type.
Set value : NORMAL, SOFT, HARD
7
Press the key.
8
Press the key several times to end the setting.
AUTO MA I NT .
CLEAN I NG <en t >
AUTO MA I NT .
CLEAN . I NTERVAL =
1 h
AUTO MA I NT .
CLEAN . I NTERVAL =
4 h
AUTO MA I NT .
CLEAN . TYPE :
NORMA L
AUTO MA I NT .
CLEAN . TYPE :
SOFT
AUTO MA I NT .
CLEAN . I NTERVAL =
4 h

Table of Contents